MIL-STD-461, Rev A, B, C, D, E   Requirements Summary

RADIOING.com - eEngineer

EMI Test Requirements Lists – Military Standards

(MIL-STD-461, Rev A, B, C, D, E)

 

MIL-STD-461A (EMI Test List)

Conducted Emissions

CE01: 30 Hz - 20 kHz (Power Leads)

CE02: 30 Hz - 20 kHz (Control/Signal Leads)

CE03: 20 kHz - 50 MHz (Power Leads)

CE04: 20 kHz - 50 MHz (Control/Signal Leads)

CE05: 30 Hz - 50 MHz (Inverse Filter Method)

CE06: 10 kHz - 10 GHz (Antenna Terminals)

Conducted Susceptibility

CS01: 20 Hz - 50 kHz (Power Leads)

CS02: 50 kHz - 400 MHz (Power Leads)

CS03: 15 kHz - 10 GHz (Intermodulation)

CS04: 15 kHz - 10 GHz (Undesired Signal Rejection)

CS05: 15 kHz - 10 GHz (Cross Modulation)

CS06: N/A (Spikes - Power Leads)

CS07: N/A (Squelch Circuits)

CS08: 30 Hz - 10 GHz (Undesired Signal Rejection)

Radiated Emissions

RE01: 30 Hz - 50k Hz (Magnetic Field)

RE02: 14 kHz - 10 GHz (Electric Field - Power Leads & Cables)

RE03: 10 kHz - 40 GHz (Ant. Spurious & Harmonics)

RE04: 20 Hz - 15 kHz (Magnetic Field)

RE05: 150 kHz - 1 GHz (Vehicle & Engine Eqpt.)

RE06: 14 kHz - 1 GHz (Overhead Power Lines)

Radiated Susceptibility

RS01: 30 Hz - 30 kHz (Magnetic Field - Eqpt & Cables)

RS02: Powerline & Spike (Magnetic Induction - Eqpt & Cables)

RS03: 14 kHz - 10 GHz (Electric Field - Eqpt & Cables)

RS04: 14 kHz - 30 MHz (Parallel Line Fields)

 

MIL-STD-461B/C (EMI Test List)

Conducted Emissions

CE01: 30 Hz - 15 kHz (Power Leads & Interconnecting Leads)

CE02: N/A

CE03: 15 kHz - 50 MHz (Power Leads & Interconnecting Leads)

CE04: N/A

CE05: N/A

CE06: 10 kHz - 26 GHz (Antenna Terminals)

CE07: Spikes, Time Domain (Power Leads)

Conducted Susceptibility

CS01: 30 Hz - 50 kHz (Power Leads)

CS02: 50 kHz - 400 MHz (Power Leads)

CS03: 15 kHz - 10 GHz (Intermodulation)

CS04: 30 kHz - 20 GHz (Undesired Signal Rejection)

CS05: 30 kHz - 20 GHz (Cross Modulation)

CS06: (Spikes - Power Leads)

CS07: (Squelch Circuits)

CS08: N/A

CS09: Structure (Common Mode) Current, 60 Hz to 100 kHz

CS10: Damped Sinusoidal Transients - Terminals, 10 kHz to 100 MHz

CS11: Damped Sinusoidal Transients - Terminals, 10 kHz to 100 MHz

Radiated Emissions

RE01: 30 Hz - 50k Hz (Magnetic Field)

RE02: 14 kHz - 10 GHz (Electric Field - Power Leads & Cables)

RE03: 10 kHz - 40 GHz (Ant. Spurious & Harmonics)

RE04: N/A

RE05: N/A

RE06: N/A

Radiated Susceptibility

RS01: 30 Hz - 50 kHz (Magnetic Field - Eqpt & Cables)

RS02: Powerline & Spike (Magnetic Induction - Eqpt & Cables)

RS03: 14 kHz - 40 GHz (Electric Field - Eqpt & Cables)

RS04: N/A

RS05: Electromagnetic Pulse Field Transient

 

MIL-STD-461D (EMI Test List)

Conducted Emissions

CE101: 30 Hz - 10 kHz (Power Leads)

CE102: 10 kHz - 10 MHz (Power Leads)

CE106: 10 kHz - 40 GHz (Antenna Terminals)

Conducted Susceptibility

CS101: 30 Hz - 50 kHz (Power Leads)

CS103: 15 kHz - 10 GHz (Ant Port Intermod)

CS104: 30 Hz - 20 GHz (Ant Port Rejection of Undesired Signals)

CS105: 30 Hz - 20 GHz (Ant Port Cross Modulation)

CS109: 60 Hz - 100 kHz (Structure Current)

CS114: 10 kHz - 400 MHz (Bulk Cable Injection)

CS115: Spikes, Impulse (Bulk Cable Injection)

CS116: 10 kHz - 100 MHz (Sinusoidal Transients - Cables & Power Leads)

Radiated Emissions

RE101: 30 Hz - 100 kHz (Magnetic Field)

RE102: 10 kHz - 18 GHz (Electric Field)

RE103: 10 kHz - 40 GHz (Antenna Spurious & Harmonics)

Radiated Susceptibility

RS101: 30 Hz - 100 kHz (Magnetic Field - Equipment & Cables

RS103: 10 kHz - 40 GHz (1000 Hz Square Wave Mod; Electric Field - Equipt & Cables)

RS105: Electromagnetic Field Transients

 

MIL-STD-461D/462D to MIL-STD-461E Changes:

MIL-STD-461E

MIL-STD-461E: "DOD Interface Standard Requirements for the Control of Electromagnetic Interference Characteristics of Subsystems and Equipment" was published on August 20, 1999 and consolidates MIL-STD-461D and MIL-STD-462D into one Standard. The associated Data Item Descriptions (DIDs) are as follows:

DID NUMBER                   DID TITLE

DI-EMCS-80199B             Electromagnetic Interference Control Procedures (EMICP)
DI-EMCS-80200B             Electromagnetic Interference Test Report (EMITR)
DI-EMCS-80201B             Electromagnetic Interference Test Procedures (EMITP)

Major changes from MIL-STD-461D/462D to MIL-STD-461E:

EUT hardware and software must be representative of production.

Susceptibility scan rates and the frequency of measurement system test checks were revised.

Conducted Emissions

CE101: is no longer applicable to shipboard equipment.

Conducted Susceptibility

CS101: applicability and limits were extended to 150 kHz.

CS109: measurement procedures were revised.

CS114: limits were revised.

CS115: applicability was revised for several equipment classes.

CS116: measurement procedures were revised; applicability was revised for several equipment classes.

Radiated Emissions

RE101: the 50 cm requirement was deleted; limits are more stringent.

RE102: limits were revised for submarine equipment.

Radiated Susceptibility

RS101: limits were revised for Navy applications; added an alternative test using the Helmholtz coil.

RS103: added use of mode-tuned reverberation chambers above 200 MHz.

RS105: limits were revised for consistency with IEC Standards.




BACK